FLAMEX 20 EN 50306-3 6x1.00 MM
FLAMEX 20 EN 50306-3 6x1.00 MM
FLAMEX
MULTICORES CONTROL CABLES
Strictly halogen free, FLAMEX EN 50306-3 & -4 control cables combine the advantages of small size, lightweight, high chemical resistance, high mechanical properties. They are recommended for installation in railway vehicles (locomotives, trains, trolleybusses...).
- Product ref. : 10276650
- Country ref. : 2PM688
Description
Description
Standards
-
ProductEN 45545-2 (HL3); EN 50264-1
-
TestEN 50305; EN 50306
DESIGN
1. Conductor
Stranded tinned copper wires
Colour: white, numbered 1 to n
2. Insulation
Thin wall, cross-linked halogen free material acc. EN 50306-2
3. Screen (for screened versions)
Tinned copper braid with optional polyester tape
4. Outer sheath
Cross-linked halogen free material
Colour: black
Example of marking: FLAMEX 239 EN 50306-3 - 300 V - number of cores x cross-section - MM-S-90 - week/year batch number
GUIDE TO USE
- Cabling rules are given in EN 50343
- Permissible current carrying capacities: values and calculation method are given in EN 50343
- Bending radius
- Static use: 5 x outer diameter
- For installation and occasional movements: 10 x outer diameter
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Type of cable
EN 50306-3
Conductor material
Tin plated copper
Conductor flexibility
Flexible stranded
Insulation colour
-
Outer sheath
Cross-linked compound
Halogen free
EN 60754-1 & EN 60684-2
Dimensional characteristics
Dimensional characteristics
Conductor cross-section
1 mm²
Conductor diameter
1.3 mm
Maximum outer diameter
7.3 mm
Minimum outer diameter
6.3 mm
Approximate weight
104 kg/km
Diameter over insulation, range
1.45 ... 1.8 mm
Number of cores
6
Electrical characteristics
Electrical characteristics
Rated Voltage Uo/U (Um)
300/500 V
Max. DC resistance of the conductor at 20°C
20 Ohm/km
Usage characteristics
Usage characteristics
Flame retardant
EN 60332-1-2
Fire retardant
EN IEC 60332-3-24 (cat C); EN IEC 60332-3-25 (EN50305)
Smoke density
EN/IEC 61034-2
Electro magnetic interference resistance
No
Gases toxicity
EN 50305-9.2
Operating temperature, range
-40 ... 90 °C
Max. conductor temperature in service
90 °C
Overload maximum core temperature
120 °C
Chemical resistance
Excellent