EN 2267-010A 012
EN 2267-010A 012
Designed for general Purpose Aircraft Wiring Applications.
UV Laser printable Wire
260°C Operating Temperature Light Weight
Arc Tracking Resistant
Descrizione
Descrizione
Norme
-
ProductEN 2267-010
DESIGN CONSTRUCTION
CORE
Stranded Conductor : Nickel Plated High
Strength Copper Alloy (AWG 26 & 24) or
Nickel Plated Copper (AWG 22 to 2)
INSULATION
Special Polyimide Tape
Special UV PTFE Tape(s)
IDENTIFICATION
Standard colour code :
White except AWG 26 which is light yellow and AWG 22 which is light green
AWG 24 is available in light blue color (EN2267-010A 002B)
Color of marking: green
Marking text: EN DR ** FR F ++
DR = Short designation
** = AWG Wire Size
FR = Country of origin (FR = France)
F = Manufacturer (F = Lynxeo)
++ = Year of production (i.e. 13 = 2013)
Caratteristiche
Caratteristiche
Caratteristiche costruttive
Caratteristiche costruttive
Colore
S
Materiale del conduttore
Rame nichelato
Materiale per l'isolamento
Special Polyimide Tape, Special UV PTFE Tape(s)
Tipo di conduttore
Conduttore a trefoli: Lega nichelata
Caratteristiche dimensionali
Caratteristiche dimensionali
Calibro (AWG)
18
Maximum core diameter
1,45 mm
minimum core diameter
1,41 mm
Diametro esterno max
1,92 mm
Minimum cable diameter
1,76 mm
Conductor stranding
19 x 0.30
Peso Massimo
14,61 g/m
Nominal weight
14,05 g/m
Caratteristiche elettriche
Caratteristiche elettriche
Frequenza massima di funzionamento
0,002 MHz
Massima resistenza el. del cond. a 20°C in c.c.
14,5 Ohm/km
Operating Voltage Vo DC
28 V
Operating voltage between phase and neutral
115 V
Operating voltage between phases
200 V
Caratteristiche d'utilizzo
Caratteristiche d'utilizzo
Temperatura Operativa
-55 ... 260 °C
Resistenza all'olio
Very good resistance to aircraft fluids
Arc tracking resistant
Sì