IEC 60502-1 Armoured (SWA) Fire retardant
IEC 60502-1 Armoured (SWA) Fire retardant
- 0.6/1 kV Power and control cables
- Armoured with galvanized steel wires (SWA) or aluminium wires (AWA)
- Oil resistant
IEC 60502-1 Armoured (AWA) 1 x 25
Product ref. 10108608
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- Armour type: Aluminium Wire
- With Green/Yellow core: No
- Number of cores: 1
- Conductor cross-section: 25 mm²
IEC 60502-1 Armoured (AWA) 1 x 35
Product ref. 10108609
- Type of conductor: Stranded, class 2
- Armour type: Aluminium Wire
- With Green/Yellow core: No
- Number of cores: 1
- Conductor cross-section: 35 mm²
IEC 60502-1 Armoured (AWA) 1 x 50
Product ref. 10108610
- Type of conductor: Stranded, class 2
- Armour type: Aluminium Wire
- With Green/Yellow core: No
- Number of cores: 1
- Conductor cross-section: 50 mm²
IEC 60502-1 Armoured (AWA) 1 x 70
Product ref. 10108611
- Type of conductor: Stranded, class 2
- Armour type: Aluminium Wire
- With Green/Yellow core: No
- Number of cores: 1
- Conductor cross-section: 70 mm²
IEC 60502-1 Armoured (AWA) 1 x 95
Product ref. 10108612
- Type of conductor: Stranded, class 2
- Armour type: Aluminium Wire
- With Green/Yellow core: No
- Number of cores: 1
- Conductor cross-section: 95 mm²
IEC 60502-1 Armoured (AWA) 1 x 120
Product ref. 10108613
- Type of conductor: Stranded, class 2
- Armour type: Aluminium Wire
- With Green/Yellow core: No
- Number of cores: 1
- Conductor cross-section: 120 mm²
IEC 60502-1 Armoured (AWA) 1 x 150
Product ref. 10108614
- Type of conductor: Stranded, class 2
- Armour type: Aluminium Wire
- With Green/Yellow core: No
- Number of cores: 1
- Conductor cross-section: 150 mm²
IEC 60502-1 Armoured (AWA) 1 x 185
Product ref. 10108615
- Type of conductor: Stranded, class 2
- Armour type: Aluminium Wire
- With Green/Yellow core: No
- Number of cores: 1
- Conductor cross-section: 185 mm²
IEC 60502-1 Armoured (AWA) 1 x 240
Product ref. 10108616
- Type of conductor: Stranded, class 2
- Armour type: Aluminium Wire
- With Green/Yellow core: No
- Number of cores: 1
- Conductor cross-section: 240 mm²
IEC 60502-1 Armoured (AWA) 1 x 300
Product ref. 10108617
- Type of conductor: Stranded, class 2
- Armour type: Aluminium Wire
- With Green/Yellow core: No
- Number of cores: 1
- Conductor cross-section: 300 mm²
IEC 60502-1 Armoured (AWA) 1 x 400
Product ref. 10108618
- Type of conductor: Stranded, class 2
- Armour type: Aluminium Wire
- With Green/Yellow core: No
- Number of cores: 1
- Conductor cross-section: 400 mm²
IEC 60502-1 Armoured (AWA) 1 x 500
Product ref. 10108619
- Type of conductor: Stranded, class 2
- Armour type: Aluminium Wire
- With Green/Yellow core: No
- Number of cores: 1
- Conductor cross-section: 500 mm²
IEC 60502-1 Armoured (AWA) 1 x 630
Product ref. 10108620
- Type of conductor: Stranded, class 2
- Armour type: Aluminium Wire
- With Green/Yellow core: No
- Number of cores: 1
- Conductor cross-section: 630 mm²
IEC 60502-1 Armoured (SWA) 2 x 1,5
Product ref. 10108621
- Type of conductor: Solid, Class 1
- Armour type: Galvanized steel wires
- With Green/Yellow core: No
- Number of cores: 2
- Conductor cross-section: 1.5 mm²
IEC 60502-1 Armoured (SWA) 2 x 1,5
Product ref. 10108622
- Type of conductor: Stranded, class 2
- Armour type: Galvanized steel wires
- With Green/Yellow core: No
- Number of cores: 2
- Conductor cross-section: 1.5 mm²
IEC 60502-1 Armoured (SWA) 2 x 2,5
Product ref. 10108623
- Type of conductor: Solid, Class 1
- Armour type: Galvanized steel wires
- With Green/Yellow core: No
- Number of cores: 2
- Conductor cross-section: 2.5 mm²
IEC 60502-1 Armoured (SWA) 2 x 2,5
Product ref. 10108624
- Type of conductor: Stranded, class 2
- Armour type: Galvanized steel wires
- With Green/Yellow core: No
- Number of cores: 2
- Conductor cross-section: 2.5 mm²
IEC 60502-1 Armoured (SWA) 2 x 4
Product ref. 10108625
- Type of conductor: Solid, Class 1
- Armour type: Galvanized steel wires
- With Green/Yellow core: No
- Number of cores: 2
- Conductor cross-section: 4 mm²
IEC 60502-1 Armoured (SWA) 2 x 4
Product ref. 10108626
- Type of conductor: Stranded, class 2
- Armour type: Galvanized steel wires
- With Green/Yellow core: No
- Number of cores: 2
- Conductor cross-section: 4 mm²
IEC 60502-1 Armoured (SWA) 2 x 6
Product ref. 10108627
- Type of conductor: Stranded, class 2
- Armour type: Galvanized steel wires
- With Green/Yellow core: No
- Number of cores: 2
- Conductor cross-section: 6 mm²
IEC 60502-1 Armoured (SWA) 2 x 10
Product ref. 10108628
- Type of conductor: Stranded, class 2
- Armour type: Galvanized steel wires
- With Green/Yellow core: No
- Number of cores: 2
- Conductor cross-section: 10 mm²
IEC 60502-1 Armoured (SWA) 2 x 16
Product ref. 10108629
- Type of conductor: Stranded, class 2
- Armour type: Galvanized steel wires
- With Green/Yellow core: No
- Number of cores: 2
- Conductor cross-section: 16 mm²
IEC 60502-1 Armoured (SWA) 2 x 25
Product ref. 10108630
- Type of conductor: Stranded, class 2
- Armour type: Galvanized steel wires
- With Green/Yellow core: No
- Number of cores: 2
- Conductor cross-section: 25 mm²
IEC 60502-1 Armoured (SWA) 2 x 35
Product ref. 10108631
- Type of conductor: Stranded, class 2
- Armour type: Galvanized steel wires
- With Green/Yellow core: No
- Number of cores: 2
- Conductor cross-section: 35 mm²
IEC 60502-1 Armoured (SWA) 2 x 50
Product ref. 10108632
- Type of conductor: Stranded, class 2
- Armour type: Galvanized steel wires
- With Green/Yellow core: No
- Number of cores: 2
- Conductor cross-section: 50 mm²
IEC 60502-1 Armoured (SWA) 2 x 70
Product ref. 10108633
- Type of conductor: Stranded, class 2
- Armour type: Galvanized steel wires
- With Green/Yellow core: No
- Number of cores: 2
- Conductor cross-section: 70 mm²
IEC 60502-1 Armoured (SWA) 2 x 95
Product ref. 10108634
- Type of conductor: Stranded, class 2
- Armour type: Galvanized steel wires
- With Green/Yellow core: No
- Number of cores: 2
- Conductor cross-section: 95 mm²
IEC 60502-1 Armoured (SWA) 2 x 120
Product ref. 10108635
- Type of conductor: Stranded, class 2
- Armour type: Galvanized steel wires
- With Green/Yellow core: No
- Number of cores: 2
- Conductor cross-section: 120 mm²
IEC 60502-1 Armoured (SWA) 2 x 150
Product ref. 10108636
- Type of conductor: Stranded, class 2
- Armour type: Galvanized steel wires
- With Green/Yellow core: No
- Number of cores: 2
- Conductor cross-section: 150 mm²
IEC 60502-1 Armoured (SWA) 2 x 185
Product ref. 10108637
- Type of conductor: Stranded, class 2
- Armour type: Galvanized steel wires
- With Green/Yellow core: No
- Number of cores: 2
- Conductor cross-section: 185 mm²
IEC 60502-1 Armoured (SWA) 2 x 240
Product ref. 10108638
- Type of conductor: Stranded, class 2
- Armour type: Galvanized steel wires
- With Green/Yellow core: No
- Number of cores: 2
- Conductor cross-section: 240 mm²
IEC 60502-1 Armoured (SWA) 2 x 300
Product ref. 10108639
- Type of conductor: Stranded, class 2
- Armour type: Galvanized steel wires
- With Green/Yellow core: No
- Number of cores: 2
- Conductor cross-section: 300 mm²
IEC 60502-1 Armoured (SWA) 3 x 1,5
Product ref. 10108640
- Type of conductor: Solid, Class 1
- Armour type: Galvanized steel wires
- With Green/Yellow core: No
- Number of cores: 3
- Conductor cross-section: 1.5 mm²
IEC 60502-1 Armoured (SWA) 3 x 1,5
Product ref. 10108641
- Type of conductor: Stranded, class 2
- Armour type: Galvanized steel wires
- With Green/Yellow core: No
- Number of cores: 3
- Conductor cross-section: 1.5 mm²
IEC 60502-1 Armoured (SWA) 3 x 2,5
Product ref. 10108642
- Type of conductor: Solid, Class 1
- Armour type: Galvanized steel wires
- With Green/Yellow core: No
- Number of cores: 3
- Conductor cross-section: 2.5 mm²
IEC 60502-1 Armoured (SWA) 3 x 2,5
Product ref. 10108643
- Type of conductor: Stranded, class 2
- Armour type: Galvanized steel wires
- With Green/Yellow core: No
- Number of cores: 3
- Conductor cross-section: 2.5 mm²
IEC 60502-1 Armoured (SWA) 3 x 4
Product ref. 10108644
- Type of conductor: Solid, Class 1
- Armour type: Galvanized steel wires
- With Green/Yellow core: No
- Number of cores: 3
- Conductor cross-section: 4 mm²
IEC 60502-1 Armoured (SWA) 3 x 4
Product ref. 10108645
- Type of conductor: Stranded, class 2
- Armour type: Galvanized steel wires
- With Green/Yellow core: No
- Number of cores: 3
- Conductor cross-section: 4 mm²
IEC 60502-1 Armoured (SWA) 3 x 6
Product ref. 10108646
- Type of conductor: Stranded, class 2
- Armour type: Galvanized steel wires
- With Green/Yellow core: No
- Number of cores: 3
- Conductor cross-section: 6 mm²
IEC 60502-1 Armoured (SWA) 3 x 10
Product ref. 10108647
- Type of conductor: Stranded, class 2
- Armour type: Galvanized steel wires
- With Green/Yellow core: No
- Number of cores: 3
- Conductor cross-section: 10 mm²
IEC 60502-1 Armoured (SWA) 3 x 16
Product ref. 10108648
- Type of conductor: Stranded, class 2
- Armour type: Galvanized steel wires
- With Green/Yellow core: No
- Number of cores: 3
- Conductor cross-section: 16 mm²
IEC 60502-1 Armoured (SWA) 3 x 25
Product ref. 10108649
- Type of conductor: Stranded, class 2
- Armour type: Galvanized steel wires
- With Green/Yellow core: No
- Number of cores: 3
- Conductor cross-section: 25 mm²
IEC 60502-1 Armoured (SWA) 3 x 35
Product ref. 10108650
- Type of conductor: Stranded, class 2
- Armour type: Galvanized steel wires
- With Green/Yellow core: No
- Number of cores: 3
- Conductor cross-section: 35 mm²
IEC 60502-1 Armoured (SWA) 3 x 50
Product ref. 10108651
- Type of conductor: Stranded, class 2
- Armour type: Galvanized steel wires
- With Green/Yellow core: No
- Number of cores: 3
- Conductor cross-section: 50 mm²
IEC 60502-1 Armoured (SWA) 3 x 70
Product ref. 10108652
- Type of conductor: Stranded, class 2
- Armour type: Galvanized steel wires
- With Green/Yellow core: No
- Number of cores: 3
- Conductor cross-section: 70 mm²
IEC 60502-1 Armoured (SWA) 3 x 95
Product ref. 10108653
- Type of conductor: Stranded, class 2
- Armour type: Galvanized steel wires
- With Green/Yellow core: No
- Number of cores: 3
- Conductor cross-section: 95 mm²
IEC 60502-1 Armoured (SWA) 3 x 120
Product ref. 10108654
- Type of conductor: Stranded, class 2
- Armour type: Galvanized steel wires
- With Green/Yellow core: No
- Number of cores: 3
- Conductor cross-section: 120 mm²
IEC 60502-1 Armoured (SWA) 3 x 150
Product ref. 10108655
- Type of conductor: Stranded, class 2
- Armour type: Galvanized steel wires
- With Green/Yellow core: No
- Number of cores: 3
- Conductor cross-section: 150 mm²
IEC 60502-1 Armoured (SWA) 3 x 185
Product ref. 10108656
- Type of conductor: Stranded, class 2
- Armour type: Galvanized steel wires
- With Green/Yellow core: No
- Number of cores: 3
- Conductor cross-section: 185 mm²
IEC 60502-1 Armoured (SWA) 3 x 240
Product ref. 10108657
- Type of conductor: Stranded, class 2
- Armour type: Galvanized steel wires
- With Green/Yellow core: No
- Number of cores: 3
- Conductor cross-section: 240 mm²
IEC 60502-1 Armoured (SWA) 3 x 300
Product ref. 10108658
- Type of conductor: Stranded, class 2
- Armour type: Galvanized steel wires
- With Green/Yellow core: No
- Number of cores: 3
- Conductor cross-section: 300 mm²
IEC 60502-1 Armoured (SWA) 4 x 1,5
Product ref. 10108659
- Type of conductor: Solid, Class 1
- Armour type: Galvanized steel wires
- With Green/Yellow core: No
- Number of cores: 4
- Conductor cross-section: 1.5 mm²
IEC 60502-1 Armoured (SWA) 4 x 1,5
Product ref. 10108660
- Type of conductor: Stranded, class 2
- Armour type: Galvanized steel wires
- With Green/Yellow core: No
- Number of cores: 4
- Conductor cross-section: 1.5 mm²
IEC 60502-1 Armoured (SWA) 4 x 2,5
Product ref. 10108661
- Type of conductor: Solid, Class 1
- Armour type: Galvanized steel wires
- With Green/Yellow core: No
- Number of cores: 4
- Conductor cross-section: 2.5 mm²
IEC 60502-1 Armoured (SWA) 4 x 2,5
Product ref. 10108662
- Type of conductor: Stranded, class 2
- Armour type: Galvanized steel wires
- With Green/Yellow core: No
- Number of cores: 4
- Conductor cross-section: 2.5 mm²
IEC 60502-1 Armoured (SWA) 4 x 4
Product ref. 10108663
- Type of conductor: Solid, Class 1
- Armour type: Galvanized steel wires
- With Green/Yellow core: No
- Number of cores: 4
- Conductor cross-section: 4 mm²
IEC 60502-1 Armoured (SWA) 4 x 4
Product ref. 10108664
- Type of conductor: Stranded, class 2
- Armour type: Galvanized steel wires
- With Green/Yellow core: No
- Number of cores: 4
- Conductor cross-section: 4 mm²
IEC 60502-1 Armoured (SWA) 4 x 6
Product ref. 10108665
- Type of conductor: Stranded, class 2
- Armour type: Galvanized steel wires
- With Green/Yellow core: No
- Number of cores: 4
- Conductor cross-section: 6 mm²
IEC 60502-1 Armoured (SWA) 4 x 10
Product ref. 10108666
- Type of conductor: Stranded, class 2
- Armour type: Galvanized steel wires
- With Green/Yellow core: No
- Number of cores: 4
- Conductor cross-section: 10 mm²
IEC 60502-1 Armoured (SWA) 4 x 16
Product ref. 10108667
- Type of conductor: Stranded, class 2
- Armour type: Galvanized steel wires
- With Green/Yellow core: No
- Number of cores: 4
- Conductor cross-section: 16 mm²
IEC 60502-1 Armoured (SWA) 4 x 25
Product ref. 10108668
- Type of conductor: Stranded, class 2
- Armour type: Galvanized steel wires
- With Green/Yellow core: No
- Number of cores: 4
- Conductor cross-section: 25 mm²
IEC 60502-1 Armoured (SWA) 4 x 35
Product ref. 10108669
- Type of conductor: Stranded, class 2
- Armour type: Galvanized steel wires
- With Green/Yellow core: No
- Number of cores: 4
- Conductor cross-section: 35 mm²
IEC 60502-1 Armoured (SWA) 4 x 50
Product ref. 10108670
- Type of conductor: Stranded, class 2
- Armour type: Galvanized steel wires
- With Green/Yellow core: No
- Number of cores: 4
- Conductor cross-section: 50 mm²
IEC 60502-1 Armoured (SWA) 4 x 70
Product ref. 10108671
- Type of conductor: Stranded, class 2
- Armour type: Galvanized steel wires
- With Green/Yellow core: No
- Number of cores: 4
- Conductor cross-section: 70 mm²
IEC 60502-1 Armoured (SWA) 4 x 95
Product ref. 10108672
- Type of conductor: Stranded, class 2
- Armour type: Galvanized steel wires
- With Green/Yellow core: No
- Number of cores: 4
- Conductor cross-section: 95 mm²
IEC 60502-1 Armoured (SWA) 4 x 120
Product ref. 10108673
- Type of conductor: Stranded, class 2
- Armour type: Galvanized steel wires
- With Green/Yellow core: No
- Number of cores: 4
- Conductor cross-section: 120 mm²
IEC 60502-1 Armoured (SWA) 4 x 150
Product ref. 10108674
- Type of conductor: Stranded, class 2
- Armour type: Galvanized steel wires
- With Green/Yellow core: No
- Number of cores: 4
- Conductor cross-section: 150 mm²
IEC 60502-1 Armoured (SWA) 4 x 185
Product ref. 10108675
- Type of conductor: Stranded, class 2
- Armour type: Galvanized steel wires
- With Green/Yellow core: No
- Number of cores: 4
- Conductor cross-section: 185 mm²
IEC 60502-1 Armoured (SWA) 4 x 240
Product ref. 10108676
- Type of conductor: Stranded, class 2
- Armour type: Galvanized steel wires
- With Green/Yellow core: No
- Number of cores: 4
- Conductor cross-section: 240 mm²
IEC 60502-1 Armoured (SWA) 4 x 300
Product ref. 10108677
- Type of conductor: Stranded, class 2
- Armour type: Galvanized steel wires
- With Green/Yellow core: No
- Number of cores: 4
- Conductor cross-section: 300 mm²
IEC 60502-1 Armoured (SWA) 5G1,5
Product ref. 10108678
- Type of conductor: Solid, Class 1
- Armour type: Galvanized steel wires
- With Green/Yellow core: Yes
- Number of cores: 5
- Conductor cross-section: 1.5 mm²
IEC 60502-1 Armoured (SWA) 5G1,5
Product ref. 10108679
- Type of conductor: Stranded, class 2
- Armour type: Galvanized steel wires
- With Green/Yellow core: Yes
- Number of cores: 5
- Conductor cross-section: 1.5 mm²
IEC 60502-1 Armoured (SWA) 5G2,5
Product ref. 10108680
- Type of conductor: Solid, Class 1
- Armour type: Galvanized steel wires
- With Green/Yellow core: Yes
- Number of cores: 5
- Conductor cross-section: 2.5 mm²
IEC 60502-1 Armoured (SWA) 5G2,5
Product ref. 10108681
- Type of conductor: Stranded, class 2
- Armour type: Galvanized steel wires
- With Green/Yellow core: Yes
- Number of cores: 5
- Conductor cross-section: 2.5 mm²
IEC 60502-1 Armoured (SWA) 5G4
Product ref. 10108682
- Type of conductor: Solid, Class 1
- Armour type: Galvanized steel wires
- With Green/Yellow core: Yes
- Number of cores: 5
- Conductor cross-section: 4 mm²
IEC 60502-1 Armoured (SWA) 5G4
Product ref. 10108683
- Type of conductor: Stranded, class 2
- Armour type: Galvanized steel wires
- With Green/Yellow core: Yes
- Number of cores: 5
- Conductor cross-section: 4 mm²
IEC 60502-1 Armoured (SWA) 5G6
Product ref. 10108684
- Type of conductor: Stranded, class 2
- Armour type: Galvanized steel wires
- With Green/Yellow core: Yes
- Number of cores: 5
- Conductor cross-section: 6 mm²
IEC 60502-1 Armoured (SWA) 5G10
Product ref. 10108685
- Type of conductor: Stranded, class 2
- Armour type: Galvanized steel wires
- With Green/Yellow core: Yes
- Number of cores: 5
- Conductor cross-section: 10 mm²
IEC 60502-1 Armoured (SWA) 5G16
Product ref. 10108686
- Type of conductor: Stranded, class 2
- Armour type: Galvanized steel wires
- With Green/Yellow core: Yes
- Number of cores: 5
- Conductor cross-section: 16 mm²
IEC 60502-1 Armoured (SWA) 5G25
Product ref. 10108687
- Type of conductor: Stranded, class 2
- Armour type: Galvanized steel wires
- With Green/Yellow core: Yes
- Number of cores: 5
- Conductor cross-section: 25 mm²
IEC 60502-1 Armoured (SWA) 5G35
Product ref. 10108688
- Type of conductor: Stranded, class 2
- Armour type: Galvanized steel wires
- With Green/Yellow core: Yes
- Number of cores: 5
- Conductor cross-section: 35 mm²
IEC 60502-1 Armoured (SWA) 5G50
Product ref. 10108689
- Type of conductor: Stranded, class 2
- Armour type: Galvanized steel wires
- With Green/Yellow core: Yes
- Number of cores: 5
- Conductor cross-section: 50 mm²
IEC 60502-1 Armoured (SWA) 5G70
Product ref. 10108690
- Type of conductor: Stranded, class 2
- Armour type: Galvanized steel wires
- With Green/Yellow core: Yes
- Number of cores: 5
- Conductor cross-section: 70 mm²
IEC 60502-1 Armoured (SWA) 5G95
Product ref. 10108691
- Type of conductor: Stranded, class 2
- Armour type: Galvanized steel wires
- With Green/Yellow core: Yes
- Number of cores: 5
- Conductor cross-section: 95 mm²
IEC 60502-1 Armoured (SWA) 5G120
Product ref. 10108692
- Type of conductor: Stranded, class 2
- Armour type: Galvanized steel wires
- With Green/Yellow core: Yes
- Number of cores: 5
- Conductor cross-section: 120 mm²
IEC 60502-1 Armoured (SWA) 5G150
Product ref. 10108693
- Type of conductor: Stranded, class 2
- Armour type: Galvanized steel wires
- With Green/Yellow core: Yes
- Number of cores: 5
- Conductor cross-section: 150 mm²
IEC 60502-1 Armoured (SWA) 5G185
Product ref. 10108694
- Type of conductor: Stranded, class 2
- Armour type: Galvanized steel wires
- With Green/Yellow core: Yes
- Number of cores: 5
- Conductor cross-section: 185 mm²
IEC 60502-1 Armoured (SWA) 5G240
Product ref. 10108695
- Type of conductor: Stranded, class 2
- Armour type: Galvanized steel wires
- With Green/Yellow core: Yes
- Number of cores: 5
- Conductor cross-section: 240 mm²
IEC 60502-1 Armoured (SWA) 5G300
Product ref. 10108696
- Type of conductor: Stranded, class 2
- Armour type: Galvanized steel wires
- With Green/Yellow core: Yes
- Number of cores: 5
- Conductor cross-section: 300 mm²
IEC 60502-1 Armoured (SWA) 7 x 1,5
Product ref. 10108697
- Type of conductor: Stranded, class 2
- Armour type: Galvanized steel wires
- With Green/Yellow core: No
- Number of cores: 7
- Conductor cross-section: 1.5 mm²
IEC 60502-1 Armoured (SWA) 7 x 2,5
Product ref. 10108706
- Type of conductor: Stranded, class 2
- Armour type: Galvanized steel wires
- With Green/Yellow core: No
- Number of cores: 7
- Conductor cross-section: 2.5 mm²
IEC 60502-1 Armoured (SWA) 10 x 1,5
Product ref. 10108698
- Type of conductor: Stranded, class 2
- Armour type: Galvanized steel wires
- With Green/Yellow core: No
- Number of cores: 10
- Conductor cross-section: 1.5 mm²
IEC 60502-1 Armoured (SWA) 10 x 2,5
Product ref. 10108707
- Type of conductor: Stranded, class 2
- Armour type: Galvanized steel wires
- With Green/Yellow core: No
- Number of cores: 10
- Conductor cross-section: 2.5 mm²
IEC 60502-1 Armoured (SWA) 12 x 1,5
Product ref. 10108699
- Type of conductor: Stranded, class 2
- Armour type: Galvanized steel wires
- With Green/Yellow core: No
- Number of cores: 12
- Conductor cross-section: 1.5 mm²
IEC 60502-1 Armoured (SWA) 12 x 2,5
Product ref. 10108708
- Type of conductor: Stranded, class 2
- Armour type: Galvanized steel wires
- With Green/Yellow core: No
- Number of cores: 12
- Conductor cross-section: 2.5 mm²
IEC 60502-1 Armoured (SWA) 14 x 1,5
Product ref. 10108700
- Type of conductor: Stranded, class 2
- Armour type: Galvanized steel wires
- With Green/Yellow core: No
- Number of cores: 14
- Conductor cross-section: 1.5 mm²
IEC 60502-1 Armoured (SWA) 14 x 2,5
Product ref. 10108709
- Type of conductor: Stranded, class 2
- Armour type: Galvanized steel wires
- With Green/Yellow core: No
- Number of cores: 14
- Conductor cross-section: 2.5 mm²
IEC 60502-1 Armoured (SWA) 19 x 1,5
Product ref. 10108701
- Type of conductor: Stranded, class 2
- Armour type: Galvanized steel wires
- With Green/Yellow core: No
- Number of cores: 19
- Conductor cross-section: 1.5 mm²
IEC 60502-1 Armoured (SWA) 19 x 2,5
Product ref. 10108710
- Type of conductor: Stranded, class 2
- Armour type: Galvanized steel wires
- With Green/Yellow core: No
- Number of cores: 19
- Conductor cross-section: 2.5 mm²
IEC 60502-1 Armoured (SWA) 24 x 1,5
Product ref. 10108702
- Type of conductor: Stranded, class 2
- Armour type: Galvanized steel wires
- With Green/Yellow core: No
- Number of cores: 24
- Conductor cross-section: 1.5 mm²
IEC 60502-1 Armoured (SWA) 24 x 2,5
Product ref. 10108711
- Type of conductor: Stranded, class 2
- Armour type: Galvanized steel wires
- With Green/Yellow core: No
- Number of cores: 24
- Conductor cross-section: 2.5 mm²
IEC 60502-1 Armoured (SWA) 27 x 1,5
Product ref. 10108703
- Type of conductor: Stranded, class 2
- Armour type: Galvanized steel wires
- With Green/Yellow core: No
- Number of cores: 27
- Conductor cross-section: 1.5 mm²
IEC 60502-1 Armoured (SWA) 27 x 2,5
Product ref. 10108712
- Type of conductor: Stranded, class 2
- Armour type: Galvanized steel wires
- With Green/Yellow core: No
- Number of cores: 27
- Conductor cross-section: 2.5 mm²
IEC 60502-1 Armoured (SWA) 30 x 1,5
Product ref. 10108704
- Type of conductor: Stranded, class 2
- Armour type: Galvanized steel wires
- With Green/Yellow core: No
- Number of cores: 30
- Conductor cross-section: 1.5 mm²
IEC 60502-1 Armoured (SWA) 30 x 2,5
Product ref. 10108713
- Type of conductor: Stranded, class 2
- Armour type: Galvanized steel wires
- With Green/Yellow core: No
- Number of cores: 30
- Conductor cross-section: 2.5 mm²
IEC 60502-1 Armoured (SWA) 37 x 1,5
Product ref. 10108705
- Type of conductor: Stranded, class 2
- Armour type: Galvanized steel wires
- With Green/Yellow core: No
- Number of cores: 37
- Conductor cross-section: 1.5 mm²
IEC 60502-1 Armoured (SWA) 37 x 2,5
Product ref. 10108714
- Type of conductor: Stranded, class 2
- Armour type: Galvanized steel wires
- With Green/Yellow core: No
- Number of cores: 37
- Conductor cross-section: 2.5 mm²
Description
Description
Standards
-
ProductIEC 60228; IEC 60502-1
-
TestIEC 60332-3-22 Cat.A
Applications
These power and control cables are used for electricity supply in low voltage installation system. They are well adapted to underground use in industrial applications where chemical and mechanical protections are needed (refinery areas, chemical plants...).
Design
Conductor:
Solid plain copper : 1.5 to 4 mm²
Stranded plain copper : 1.5 to 630 mm²
Insulation:
Cross-linked polyethylene (XLPE)
Bedding (optional):
Inner sheath acting as a filler with practically zero thickness or assembling polyester tape
Inner covering (inner sheath):
Polyvinyl chloride (PVC) Colour :black
Armour:
Galvanized steel wires (SWA) or aluminium wires (AWA) for 1 core cable
Outer sheath:
Polyvinyl chloride (PVC). Colour: black. Other colour on request.
Core identification
1 core: black
2x to 5G cores: according to HD 308 S2
Above 5 cores: black core printed with white number.
Marking
NEXANS 279 XLPE/PVC/AWA or SWA/PVC 0.6/1 kV Nber of cores and cross section Cu IEC 60332-3-22(A) MM YYYY manufacturing number + meter marking
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Electrical characteristics
Electrical characteristics
Mechanical characteristics
Mechanical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Documentation
Selling & delivery Information
Other fire performances IEC 60332-1 or IEC 60332-3 -24(C) and enhanced hydrocarbon resistance on request.
Minimum bending radius:
1 core: 10 x outer diameter
Multicores: 8 x outer diameter
To be doubled during laying operations
Cables with reduced neutral on request